SensataSensata
RP-1B 120v low sensitivity dedicated voltage 3 wire120v low sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-1B 120v low sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75738
SensataSensata
RP-4A 277v low sensitivity 3 wire thermal protector277v low sensitivity 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-4A 277v low sensitivity 3 wire thermal protector Automatic resetting device causes fixture light to blink in fault condition. Sensitivity to thermal conditions 50/60 ...
Part No: 75735
SensataSensata
RP-13A 120v high sensitivity dedicated voltage 3 wire120v high sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-13A 120v high sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75746
SensataSensata
RP-7A 208v low sensitivity 4wire for multi-tap ballasts208v low sensitivity 4wire thermal protector for multi-tap ballasts
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-7A 208v low sensitivity 4wire thermal protector for multi-tap ballasts The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with all common wires The yellow wire of the RP-7A is connected to the 208 Volt tap of the ballast The blue wire is then connected to the tap of the ballast which will match ...
Part No: 75740
SensataSensata
RP-10A 220V low sensitivity dedicated voltage 3 wire220V low sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-10A 220V low sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75743
SensataSensata
RP-11A 120v low sensitivity 4wire for multi-tap ballasts120v low sensitivity 4wire thermal protector for multi-tap ballasts
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-11A 120v low sensitivity 4wire thermal protector for multi-tap ballasts The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with all common wires The red wire of the RP-11A is connected to the 120 Volt tap of the ballast The blue wire is then connected to the tap of the ballast which will match the ...
Part No: 75744
SensataSensata
RP-14A 240v high sensitivity dedicated voltage 3 wire240v high sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-14A 240v high sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75747
SensataSensata
RP-18A 277v high sensitivity 4wire for multi-tap ballasts277v high sensitivity 4wire thermal protector for multi-tap ballasts
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-18A 277v high sensitivity 4wire thermal protector for multi-tap ballasts The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with all common wires The orange wire of the RP-18A is connected to the 277 Volt tap of the ballast The blue wire is then connected to the tap of the ballast which will match ...
Part No: 75750
SensataSensata
RP-6A 240v low sensitivity dedicated voltage 3 wire240v low sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-6A 240v low sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75739
SensataSensata
RP-8A 120v low sensitivity dedicated voltage 3 wire120v low sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-8A 120v low sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75741
SensataSensata
RP-9A 12V low sensitivity dedicated voltage 3 wire12V low sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-9A 12V low sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75742
SensataSensata
S70-3002 R-type bulb changer attacment, threaded end fits all changersR-type bulb changer attacment, threaded end fits all changers, for R- type bulbs
(2)
  • Status: Available
  • Case Qty: 1
  • Country of Origin: Unites States
  • Weight: 0.14
Reflector shaped light bulb ...
Part No: 75824
SensataSensata
RP-15A 208v high sensitivity 4wire for multi-tap ballasts208v high sensitivity 4wire thermal protector for multi-tap ballasts
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-15A 208v high sensitivity 4wire thermal protector for multi-tap ballasts The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with all common wires The yellow wire of the RP-15A is connected to the 208 Volt tap of the ballast The blue wire is then connected to the tap of the ballast which will match ...
Part No: 75748
SensataSensata
RP-17A 220V high sensitivity dedicated voltage 3 wire220V high sensitivity dedicated voltage 3 wire thermal protector
(2)
  • Status: Available
  • Case Qty: 1
  • Weight: 0.1
Sensata RP-17A 220V high sensitivity dedicated voltage 3 wire thermal protector 3 wire RP for Dedicated Voltage The black lead wire is always connected to the input live wire The white wire is the common which is permanently connected at the factory with an extra six inch piece of wire of the same color The third wire of the RP is permanently connected to the live side of the ...
Part No: 75749